EasyManua.ls Logo

Studer OnAir 2500 - Page 197

Studer OnAir 2500
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OnAir 2500/OnAir 3000 Digital Mixing Consoles
6-62 Conguration
Date printed: 22.07.08
SW V3.0
OnAir 2500/OnAir 3000 Digital Mixing Consoles
Conguration 6-63
Date printed: 22.07.08
SW V3.0
Example 4, Pulse Output Mode: To get a pulse at the output pin, the “Triggered Edge” attribute must be set
to either “rising” or “falling”, the “Time” attribute (> 0 ms) denes the pulse
duration.
Pin Attributes Setting Pin Attributes Setting
Activate
On
Activate
On
Time
> 0 ms
Time
> 0 ms
Polarity
positive
Polarity
negative
Triggered Edge
rising
Triggered Edge
rising
Pin Attributes Setting Pin Attributes Setting
Activate
On
Activate
On
Time
> 0 ms
Time
> 0 ms
Polarity
positive
Polarity
negative
Triggered Edge
falling
Triggered Edge
falling
Key Conguration Examples: The OnAir 2500’s F 1...F 5 keys are normally used to control GPOs. This is
congured as follows:
A SNAP 1...SNAP 6 key configuration example is given in chapter 6.5.32.3.