11.11 o: Keypad-Related Settings
1030 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
■ o5-05: Log Monitor Data 3
No.
(Hex.)
Name Description
Default
(Range)
o5-05
(1555)
RUN
Log Monitor Data 3
Sets the data log monitor. This parameter is only available on an LCD
keypad.
103
(000,101 - 855)
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99].
For example, to show U1-05 [Motor Speed], set o5-05 = 105. When it is not necessary to set data log monitors, set this parameter to
000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].
■ o5-06: Log Monitor Data 4
No.
(Hex.)
Name Description
Default
(Range)
o5-06
(1556)
RUN
Log Monitor Data 4
Sets the data log monitor. This parameter is only available on an LCD
keypad.
107
(000,101 - 855)
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99].
For example, to show U1-05 [Motor Speed], set o5-03 = 105. When it is not necessary to set data log monitors, set this parameter to
000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].
■ o5-07: Log Monitor Data 5
No.
(Hex.)
Name Description
Default
(Range)
o5-07
(1557)
RUN
Log Monitor Data 5
Sets the data log monitor. This parameter is only available on an LCD
keypad.
108
(000,101 - 855)
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99].
For example, to show U1-05 [Motor Speed], set o5-07 = 105. When it is not necessary to set data log monitors, set this parameter to
000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].
■ o5-08: Log Monitor Data 6
No.
(Hex.)
Name Description
Default
(Range)
o5-08
(1558)
RUN
Log Monitor Data 6
Sets the data log monitor. This parameter is only available on an LCD
keypad.
000
(000,101 - 855)
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99]. For example, to show U1-05 [Motor Speed], set o5-08 = 105. When it is not
necessary to set data log monitors, set this parameter to 000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].
■ o5-09: Log Monitor Data 7
No.
(Hex.)
Name Description
Default
(Range)
o5-09
(1559)
RUN
Log Monitor Data 7
Sets the data log monitor. This parameter is only available on an LCD
keypad.
000
(000,101 - 855)
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99].
For example, to show U1-05 [Motor Speed], set o5-09 = 105. When it is not necessary to set data log monitors, set this parameter to
000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].