2.24 Protect the Drive during Failures
132 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Drive Model
Maximum Applicable
Motor Output
kW (HP)
Input Voltage < 460 V
Maximum Applicable
Motor Output
kW (HP)
Input Voltage ≥ 460 V
Input Current Rating
A
Semiconductor
Protection Fuse Rated
Current
Manufacturer: EATON/
Bussmann
4389 200 (250) 220 (300) 373 FWH-1000A
4453 220 (300) 260 (350) 410 FWH-1200A
4568 250 (335) 300 (400) 465 FWH-1200A
4675 315 (400) 335 (450) 584
FWH-1400A
FWH-1600A
*1
*1 Yaskawa recommends a fuse with a large rated current for applications with repeated loads.