Parameter List
10
10.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 639
No.
*1
Name Unit Default
-
Drive
Model
- 4075 4089 4103 4140
C6-01
Normal /
Heavy
Duty
Selection
-
HD1 ND1 HD1 ND1 HD1 ND1 HD1 ND1
0 1 0 1 0 1 0 1
o2-04
Drive
Model
(KVA)
Selection
Hex. A1 A2 A3 A4
E2-11
(E4-11)
Motor
Rated
Power
(kW)
kW 30 37 37 45 45 55 55 75
b3-04
V/f Gain
during
Speed
Search
% 100 100 100 100 100 80 80 80
b3-06
Speed
Estimation
Current
Level 1
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.7
b3-08
Speed
Estimation
ACR P
Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8
b3-26
Direction
Determina
tion Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy
Saving
Filter Time
s 0.50 0.50 0.50 0.50 0.50 2.00 2.00 2.00
b8-04
Energy
Saving
Coefficient
Value
- 92.54 76.32 76.32 71.56 71.56 67.2 67.2 46.2
C5-17
(C5-37)
Motor
Inertia
kgm
2
0.220 0.273 0.273 0.333 0.333 0.490 0.49 0.90
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor
Rated
Current
(FLA)
A 52.3 65.6 65.6 79.7 79.7 95 95 130
E2-02
(E4-02)
Motor
Rated Slip
Hz 1.8 1.33 1.33 1.6 1.6 1.46 1.46 1.39
E2-03
(E4-03)
Motor No-
Load
Current
A 10.9 19.1 19.1 22 22 24 24 36
E2-05
(E4-05)
Motor
Line-to-
Line
Resistance
Ω 0.269 0.155 0.155 0.122 0.122 0.088 0.088 0.092
E2-06
(E4-06)
Motor
Leakage
Inductance
% 20.7 18.8 18.8 19.9 19.9 20 20 20
E2-10
(E4-10)
Motor Iron
Loss
W 750 925 925 1125 1125 1260 1260 1600
E5-01
PM Motor
Code
Selection
- 1242 1242 1243 1243 1244 1244 1245 1245

Table of Contents