10.22 Parameters Changed by PM Motor Code Selection
666 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No. Name Unit Motor Code (setting value of E5-01)
n5-02
Motor
Acceleration Time
s 0.083 0.079 0.118 0.105 0.157 0.156 0.172 0.169
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -14.6 -16.4 -11.8 -10.5 -14.5 -17.4 -13.8 -17.5
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).
Table 10.28 SST4 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 2332 2333 2335 2336 2338 233A 233B 233D
Voltage Class V 400 400 400 400 400 400 400 400
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
Motor Rotation
Speed
min
-1
1450 1450 1450 1450 1450 1450 1450 1450
E5-02
PM Motor Rated
Power (kW)
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0
E5-03
PM Motor Rated
Current (FLA)
A 0.91 1.67 3.02 4.74 7.08 10.21 13.96 20.5
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 12.616 7.340 2.724 1.232 1.509 1.112 0.720 0.393
E5-06
PM d-axis
Inductance (mH/
phase)
mH 113.84 77.84 40.00 27.52 31.73 23.09 25.28 13.36
E5-07
PM q-axis
Inductance (mH/
phase)
mH 157.16 103.56 60.80 37.00 40.88 34.39 35.20 18.44
E5-09
PM Back-EMF
Vpeak (mV/(rad/
s))
mVs/rad 490.8 513.8 543.7 520.3 580.8 602.7 601.5 584.6
E5-24
PM Motor
Induced Voltage
Constant 2 (Ke)
mV/(r/
min)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output
Frequency
Hz 72.5 72.5 72.5 72.5 72.5 72.5 72.5 72.5
E1-05
Maximum Output
Voltage
V 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5 72.5 72.5
E1-09
Minimum Output
Frequency
Hz 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6
C5-17 Motor Inertia kgm
2
0.0016 0.0022 0.0081 0.0133 0.0133 0.017 0.027 0.044
L3-24
*1
Motor Accel Time
for Inertia Cal
s 0.092 0.068 0.125 0.139 0.083 0.070 0.082 0.092
n5-02
Motor
Acceleration Time
s 0.092 0.068 0.125 0.139 0.083 0.070 0.082 0.092
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -9.5 -9.4 -13.7 -10.0 -12.9 -19.9 -22.8 -19.8
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).