10.22 Parameters Changed by PM Motor Code Selection
668 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No. Name Unit Motor Code (setting value of E5-01)
E5-03
PM Motor Rated
Current (FLA)
A 153.1 191.7 226.0 268.8 331.3 422.9
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 0.024 0.015 0.011 0.007 0.006 0.003
E5-06
PM d-axis
Inductance (mH/
phase)
mH 2.20 1.34 1.23 0.92 0.84 0.61
E5-07
PM q-axis
Inductance (mH/
phase)
mH 3.23 2.16 1.67 1.30 1.25 0.89
E5-09
PM Back-EMF
Vpeak (mV/(rad/
s))
mVs/rad 708.0 637.8 677.0 661.7 687.1 655.9
E5-24
PM Motor
Induced Voltage
Constant 2 (Ke)
mV/(r/
min)
0.0 0.0 0.0 0.0 0 0.0
E1-04
Maximum Output
Frequency
Hz 72.5 72.5 72.5 72.5 72.5 72.5
E1-05
Maximum Output
Voltage
V 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5
E1-09
Minimum Output
Frequency
Hz 3.6 3.6 3.6 3.6 3.6 3.6
C5-17 Motor Inertia kgm
2
0.82 0.96 1.60 1.95 2.82 3.70
L3-24
*1
Motor Accel Time
for Inertia Cal
s 0.210 0.201 0.279 0.281 0.325 0.341
n5-02
Motor
Acceleration Time
s 0.210 0.201 0.279 0.281 0.325 0.341
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -19.6 -24.1 -15.1 -17.0 -19.8 -19.3
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).
Table 10.31 SST4 Series Motor Code Setting for Specification of 200 V at 1150 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 2402 2403 2405 2406 2408 240A 240B 240D
Voltage Class V 200 200 200 200 200 200 200 200
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
Motor Rotation
Speed
min
-1
1150 1150 1150 1150 1150 1150 1150 1150
E5-02
PM Motor Rated
Power (kW)
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0
E5-03
PM Motor Rated
Current (FLA)
A 1.77 3.44 5.94 9.17 14.79 20.21 27.40 39.0
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 2.680 1.520 1.071 0.542 0.362 0.295 0.162 0.115
E5-06
PM d-axis
Inductance (mH/
phase)
mH 30.55 15.29 17.48 11.98 8.60 9.54 5.31 4.44