Parameter Details
11
11.2 A: Initialization Parameters
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 685
User Parameter No. Parameter No. Saved Name
A2-03 b6-01 Dwell Reference at Start
A2-04 b6-02 Dwell Time at Start
A2-05 C1-01 Acceleration Time 1
A2-06 C1-02 Deceleration Time 1
A2-07 C6-02 Carrier Frequency Selection
A2-08 d1-01 Reference 1
A2-09 d1-02 Reference 2
A2-10 d1-03 Reference 3
A2-11 E1-08 Mid Point A Voltage
A2-12 H2-01 Term M1-M2 Function Selection
A2-13 L1-01 Motor Overload (oL1) Protection
A2-14 L4-01 Speed Agree Detection Level
A2-15 L6-02 Torque Detection Level 1
A2-16 L6-03 Torque Detection Time 1
7 : Crane (Traveling)
The drive automatically sets the parameters in Table 11.16 for a traveling application.
Table 11.16 Optimal Settings for Traveling Applications
No. Name Optimal Value
A1-02 Control method selection 0: V/f Control
b1-01 Frequency Reference Selection 1 0: Keypad
C1-01 Acceleration Time 1 3.0 s
C1-02 Deceleration Time 1 3.0 s
C6-01 Normal / Heavy Duty Selection 0: Heavy Duty Rating
C6-02 Carrier Frequency Selection 2: 5.0 kHz (4.0 kHz for AOLV/PM)
d1-01 Reference 1 6.00 Hz
d1-02 Reference 2 30.00 Hz
d1-03 Reference 3 50.00 Hz
H1-05 Terminal S5 Function Selection 3: Multi-Step Speed Reference 1
H1-06 Terminal S6 Function Selection 4: Multi-Step Speed Reference 2
H2-01 Term M1-M2 Function Selection 37: During Frequency Output
H2-02 Term M3-M4 Function Selection 37: During Frequency Output
H3-06 Terminal A3 Function Selection 1F: Not Used
L3-04 Stall Prevention during Decel 0: Disabled
L8-05 Input Phase Loss Protection Sel 1: Enabled
L8-07 Output Phase Loss Protection Sel 1: Fault when one phase is lost
L8-38 Carrier Frequency Reduction 1: Enabled below 6 Hz
L8-41 High Current Alarm Selection 1: Enabled
Parameters in Table 11.17 as user parameters.
Table 11.17 Parameters Saved as User Parameters with the Traveling Preset
User Parameter No. Parameter No. Saved Name
A2-01 b1-01 Frequency Reference Selection 1
A2-02 C1-01 Acceleration Time 1
A2-03 C1-02 Deceleration Time 1