11.8 H: Terminal Functions
894 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
The drive ramps to stop in the set deceleration time. Fault relay output terminal MA-MC activates and terminal
MB-MC deactivates.
1 : Coast to Stop
The drive output shuts off and the motor coasts to stop. Fault relay output terminal MA-MC activates and terminal
MB-MC deactivates.
2 : Fast Stop (Use C1-09)
The drive stops the motor in the deceleration time set in C1-09 [Fast Stop Time]. Fault relay output terminal MA-
MC activates and terminal MB-MC deactivates.
3 : Alarm Only
The keypad shows CP2 and the drive continues operation at the current frequency reference.
Note:
The output terminal set for Alarm [H2-01 to H2-03 = 10] activates.
4 : Digital Output Only
H2-36: Comparator 1 Ineffective Time
No.
(Hex.)
Name Description
Default
(Range)
H2-36
(159E)
Comparator 1
Ineffective Time
Sets the length of time that CP1 [Comparator1 Limit Fault] is disabled.
0.0 s
(0.0 - 10.0 s)
Note:
After you enter a Run command and wait for the time set in this parameter, the drive will monitor operation and make sure that it is in
the Comparator 1 range until you enter the Stop command.
When CP1 detection is disabled, the drive will trigger a digital output.
H2-37: Comparator 2 Ineffective Time
No.
(Hex.)
Name Description
Default
(Range)
H2-37
(159F)
Comparator 2
Ineffective Time
Sets the length of time that CP2 [Comparator2 Limit Fault] is disabled.
0.0 s
(0.0 - 10.0 s)
Note:
After you enter a Run command and wait for the time set in this parameter, the drive will monitor operation and make sure that it is in
the Comparator 2 range until you enter the Stop command.
When CP2 detection is disabled, the drive will trigger a digital output.
H2-40: Mbus Reg 15E0h bit0 Output Func
No.
(Hex.)
Name Description
Default
(Range)
H2-40
(0B58)
Mbus Reg 15E0h bit0
Output Func
Sets the MFDO for bit 0 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1A7)
H2-41: Mbus Reg 15E0h bit1 Output Func
No.
(Hex.)
Name Description
Default
(Range)
H2-41
(0B59)
Mbus Reg 15E0h bit1
Output Func
Sets the MFDO for bit 1 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1A7)
H2-42: Mbus Reg 15E0h bit2 Output Func
No.
(Hex.)
Name Description
Default
(Range)
H2-42
(0B5A)
Mbus Reg 15E0h bit2
Output Func
Sets the MFDO for bit 2 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1A7)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV