Chapter 2 INDIVIDUAL FORMATS FOR VG CONTROL COMMANDS
2.137 INDC4 [24H 21H]: Program No. incrementing /
decrementing
Function: This command increments or decrements the program number (or timing or
pattern number), and executes the program.
Sequence: Type 2
Command:
Fig. 2-137-1
* This command increments or decrements the numbers on the basis of the current
status of the VG generator.
Example 1: When the VG generator is in the internal timing data execution status
(Category: All)
→ Internal timing data numbers 1001 to 2000 are subject to incrementing
or decrementing.
Example 2: When the VG generator is in the user data (CompactFlash card or
internal flash memory) execution status (Category: All)
→ User data numbers 1 to 1000 are subject to incrementing or
decrementing.
Example 3: When the VG generator is in the internal timing data execution status
(Category: VESA)
→ Internal timing data numbers 1001 to 2000 for which VESA has been
set as the categories are subject to incrementing or decrementing.