Chapter 4 INDIVIDUAL FORMATS FOR CONTROL COMMANDS
399
4.50 LDC [60H]: D connector output condition readout
Function: This command reads the D connector output conditions of the designated
program number.
Sequence: Type 3
Command:
STX
1 byte
02H
LDC
1 byte
60H
Program number
1 to 3 bytes
“0” to “999”
ETX
1 byte
03H
Fig. 4-50-1
Data: Same as Fig. 4-49-2.