EasyManua.ls Logo

ASTRO VG-871 - LOT3 [A6 H]: All Output Condition Data Readout (Type 3)

ASTRO VG-871
499 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
380
4.32 LOT3 [A6H]: All output condition data readout
(Type 3)
Function: This command reads all the analog and digital output condition data of the
designated program number.
Sequence: Type 3
Command:
STX
1 byte
02H
LOT3
1 byte
A6H
Program number
1 to 3 bytes
“0” to “999”
ETX
1 byte
03H
Fig. 4-32-1
Data: Same as Fig. 4-31-2.