EasyManua.ls Logo

ASTRO VG-871 - SPT4 [20 H 2 CH]: Pattern Data Registration

ASTRO VG-871
499 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 INDIVIDUAL FORMATS FOR VG CONTROL COMMANDS
41
2.13 SPT4 [20H 2CH]: Pattern data registration
Function: This command registers the pattern data of the designated program. It
selects the pattern block to be set as a parameter and sends the
corresponding data. When the program number is 0, it writes the data into
the buffer RAM. When it is 9999, it writes the data into the command work
RAM.
Sequence: Type 2
Command:
STX
1 byte
02H
VG4CMD
1 byte
FDH
SPT4
2 bytes
20H 2CH
Program number
1 to 4 bytes
“0” to “1000”, “9999”
,
1 byte
2CH (Delimiter)
Pattern block No.
1 or 2 bytes
“1” = Foreground color
“2” = Character
“3” = Crosshatch
“4” = Dot
“5” = Circle
“6” = Burst
“7” = Window
“8” = Cursor
“9” = Pattern name
“10” = Color bar
“11” = Gray scale
“12” = Ramp
“13” = Sweep
“14” = Monoscope
“15” = Raster
“16” = Checker
“17” = Optional pattern
“18” = Background color
“19” = Aspect ratio
,
1 byte
2CH (Delimiter)
Pattern data
? bytes
Refer to Figs. 2-13-2 to 16.
ETX
1 byte
03H
Fig. 2-13-1
(1) Graphic color data
R
1 to 5 bytes
“0” to “65535”
,
1 byte
2CH (Delimiter)
G
1 to 5 bytes
“0” to “65535”
,
1 byte
2CH (Delimiter)
B
1 to 5 bytes
“0” to “65535”
,
1 byte
2CH (Delimiter)
Edit Bit Mode
1 or 2 bytes
“8” to “16”
Fig. 2-13-2

Table of Contents