System Configuration 287
© 2020, ATEÏS. All rights reserved.
5.4.18 Redundancy
Allow to set the redundancy system used for IDA8.
1. Open [Device Management] window.
2. Search and connect to the device.
3. Click [Redundancy] to open [Redundancy Configuration] window.
Redundancy System: Choose the network the desired secondary system is in, the device list
will change with this item.
Evac Input Control Channel: The channel which is connected to the redundancy units.
Device List: Shows how many units in the secondary system and their serial numbers.
4. Once the setting is done, press the "Configure" button and you can see the redundancy
information shows at the device Information column as shown in the picture below. The two
system becoming each other's backup system.
5.5 3rd Party Control
5.5.1 Ateis 3rd Party Control
Depending on the device, Ateis 3rd party protocol allows an external device to control an Ateis
device through Ethernet or RS232.
5.5.1.1 Assign Elements to 3rd Party Control
To let an element controllable by 3rd party protocol, right click the element and click [3rd Party
Control > Single] on the pop-up window. See the picture as below,