o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.31 Backup AMP Out of Toler
The reference value measured from the backup amplifier is out of tolerance.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o The text messages display at the touch screen of the IDA8C:
"Backup AMP Out of Toler."
"Zone n Backup AMP Gain Too High"
"Zone n Backup AMP Gain Too Low " (Where n = 1~8)
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.32 IP Attack
The local ATEIS net card has failed.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o System Fault LED on the front panel of the IDA8C/S.
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "Local Netcard Boot Failure" message displays on the touch screen of the IDA8C.
o A text message displays at the [IP Attack] window in Ateis Studio, see the picture as
below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.