Fault List & Troubleshooting 467
© 2020, ATEÏS. All rights reserved.
o EVAC Input Error (Short):
Text messages display on the touch screen of IDA8C:
"URGP 32I Fault"
"Port:1 IP:1, ch1 Short", where Port N is the Nth PDC port for a peripheral
connection. The IP is the unique number for each peripheral device on the PDC
port, ch is the number of the channel.
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
Fault Handling : URGP Fault
7.1.16 Remote Fault
An error is detected on peripheral devices. For PPM-AS or PSS-AS, this fault relates to a capsule
microphone or a speaker error.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log
o PPM-AS / PSS-AS Capsule Microphone Open or Short / Speaker Error:
The text messages display on the touch screen of IDA8C:
"Remote Fault"