Fault List & Troubleshooting 475
© 2020, ATEÏS. All rights reserved.
7.1.33 NT PHY Error
The system detection of Ateis Local/Global-Net card is broken.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "NT PHY Error" message displays at the touch screen of the IDA8C.
o The text messages display at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
LNT: Error in Ateis Local Net Card. Note: GNT: Ateis Global Net Card.
Port A PHY Error: Error in A/B Port Net Card.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
7.1.34 Local AteisNet PA/B Shutdown
The local Ateis-Net card has detected unknown communication and causes the port is disable,
users need to reboot the machine.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "Local AteisNet PA/B Shutdown" message displays at the touch screen of the IDA8C.
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
7.1.35 Global AteisNet PA/B Shutdown
The global Ateis-Net card has detected unknown communication and causes the port is disable,
users need to reboot the machine.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o "Global AteisNet PA/B Shutdown" message displays at the touch screen of the IDA8C.
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.