System Configuration 321
© 2020, ATEÏS. All rights reserved.
Amplifier:
Indicate a row is related to a normal amplifier of a zone.
Monitor:
Enable/disable the normal amplifier monitoring for the selected zone. If the monitoring of a
normal amplifier is disabled, the IDA8C/S will not detect faults of the normal amplifiers.
Tolerance (%):
To determine the boundary of the fault detection for a selected zone. If one of the following
conditions meets the description below, IDA8 will recognize the fault.
o Measure < (Full Loaded Reference x (100% - Tolerance%))
o Measure > (Unloaded Reference x (100% + Tolerance%))
Global Tolerance:
Click to change the tolerance setting on [Tolerance%] grid for all the zones of normal amplifier,
which connected to all of the IDA8 processors. If the zone is not been selected on [Global
Tolerance] grid, the tolerance value will not change.
Get Reference:
Get the reference values of the selected zone for further fault detection. Be aware, the hardware
configuration(IDA8C/S, amplifiers, wiring) should be completed before getting the reference.
Get All Reference:
Get the reference of gain value from the selected IDA8 processor.
Global Get Reference:
Get all the reference of gain value from all the IDA8 processors.
Reset All Reference:
Reset the reference of gain value from the selected IDA8 processor.
Reset Reference:
Clear the reference values of the selected zone to initialize the status. If the reference value is
cleared, the monitoring will stop.
Global Reset Reference: