which balances out the signal to make it sound more professional.
Control Window
Bypass: Disable the expander's function.
Soft Knee: Enable/disable the “Soft Knee
mode.
Expand: Indicate that the function is
active.
Ratio: Set the expansion ratio.
Threshold: Set the threshold level above which
expansion begins.
Threshold Range: Set the range of level, in which
the ratio gradually alters from 1:1 to the value set by
the ratio parameter (Soft Knee function).
Attack Time: Set the time it takes to respond to the
input signal.
Release Time: Adjust the time to stop the gain
reduction.
Gain Reduction: Reflect the current amount of gain
reduction.
Graphical Control Window
Axis:
o X/Y: Input/output signal level(dB).
Control Points:
o Red: Adjust Ratio.
o Yellow: Adjust the range of Threshold.
o Blue: Adjust Threshold.