2. By Front screen panel of PSS AS unit
Users can also check by the color and the name of main function buttons on PSS AS unit
between Local and Global version have slightly different. See the picture below,
If your PSS-AS is match with the software, please move to Step 3 - Software Setting. If not,
please continue the modification by the following solution below.
Solution:
If your software version or firmware version for each device isn't match with the same version,
update or rollback your software & firmware version (Local version <=> Global version). See the
example below,
Example (Software & Firmware):
If the current version of your IDA8 controller on Ateis Studio software is Global version (2.X.X.XX),
yet PSS AS unit is Local version (1.X.X.XX),
1) First, download the update code to rollback the global version of your IDA8 controller to
local version for connecting with your PSS AS unit functionally.
[IDA8 controller: Global version (2.X.X.XX) => Local version (1.X.X.XX)]
2) Then, download the update code to update the local version of your PSS AS unit to
Global version.
[PSS AS unit: Local version (1.X.X.XX) => Global version (2.X.X.XX)]
3) Last, download the update code to update the local version of your IDA8 controller to
global version for connecting with your PSS AS unit.
[IDA8 controller: Local version (1.X.X.XX) => Global version (2.X.X.XX)]
If users have the previous update code for local/global version matching with your software,