892-0000010B OM
154
IT IS FORBIDDEN TO MODIFY THE INPUT VALUES OF ALL OTHER PARAMETERS
(FACTORY DEFAULTS).
As the instrument scale illumination is activated, i.e. when central light switch 10 (Figure 2.23.1)
is turned to position II “Dashboard illumination, marker lights are ON” and to position III “Loads of
position II and front headlights are ON”, the brightness of the integrated display and of the segments
of the PTO indicator is automatically reduced.
3.14.5 Installation and adjustment of speed sensors
To install the speed sensor (both right and left), you must do the following:
- set driven gear 7 (Figure 3.14.3) with a tooth opposite the hole in the cover of rear
axle 1;
- to ensure clearance S, measure dimension H and install the required number of
shims 6, according to Table 3.14.3;
- put ground wire 4 of sensor 2 under any of bolts 3 with spring washer 5;
- use sealing compound for bolts 3 and tighten to a torque of 10 to 15 Nm.
1 – rear axle cover; 2 – speed sensor; 3 - bolt; 4 – ground wire; 5 - spring washer; 6 - gas-
ket; 7 - driven gear.
Figure 3.14.3 - Installation of speed sensors
Table 3.14.3 – Installation of speed sensor
H, mm
Amount of shims 6
(Figure 3.14.3)
S, mm
11,25 - 12,00 5 2,05-2,80
12,10 - 13,00 4 1,90-2,80
13,10 – 13,80 3 1,90-2,60