EasyManuals Logo

Cisco SGE2000 - Cisco - Gigabit Switch Administration Guide

Cisco SGE2000 - Cisco - Gigabit Switch
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
Configuring Device Security
Defining DoS Prevention
Cisco Small Business SFE/SGE Managed Switches Administration Guide 124
4
STEP 1 Click Security Suite > DoS Prevention > Global Settings. The
Global Settings Page
opens:
Global Settings Page
The
Global Settings Page
contains the following fields:
Security Suite Status — Indicates if DoS security is enabled on the device. The
possible field values are:
Enabled
— Enables DoS security.
Disabled
— Disables DoS security on the device. This is the default value.
Denial of Service Protection — Indicates if any of the services listed below are
enabled. If the service protection is disabled, the
Stacheldraht Distribution
,
Invasor Trojan
, and
Back Orifice Trojan
fields
are disabled.
Stacheldraht Distribution — Discards TCP packets with source TCP port equal
to 16660
Invasor Trojan — Discards TCP packets with destination TCP port equal to
2140 and source TCP port equal to 1024.
Back Orifice Trojan — Discards UDP packets with destination UDP port equal
to 31337 and source UDP port equal to 1024.
STEP 2 Define the relevant fields.

Table of Contents

Other manuals for Cisco SGE2000 - Cisco - Gigabit Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 - Cisco - Gigabit Switch and is the answer not in the manual?

Cisco SGE2000 - Cisco - Gigabit Switch Specifications

General IconGeneral
Form FactorRack-mountable
Switching Capacity48 Gbps
Forwarding Rate35.7 Mpps
LayerLayer 2
Power SupplyInternal
ManagementWeb-based, SNMP, CLI
MAC Address Table Size8000 entries
VLANs256
FeaturesQuality of Service (QoS), IGMP snooping, Port mirroring
Dimensions (W x D x H)440 x 257 x 44 mm (17.3 x 10.1 x 1.73 in)
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x