Number of Retries — Defines the number of transmitted requests sent to
RADIUS server before a failure occurs. The possible field values are 1 - 10.
Three is the default value.
Timeout for Reply — Defines the amount of the time in seconds the device
waits for an answer from the RADIUS server before retrying the query, or
switching to the next server. The possible field values are 1 - 30. Three is the
default value.
Dead Time — Defines the amount of time (minutes) that a RADIUS server is
bypassed for service requests. The range is 0-2000. The Dead Time default is
0 minutes.
Key String — Defines the default key string used for authenticating and
encrypting all RADIUS communications between the device and the RADIUS
server. This key must match the RADIUS encryption.
Usage Type — Specifies the RADIUS server authentication type. The default
value is Login. The possible field values are:
-
Login
— Indicates that the RADIUS server is used for authenticating user
name and passwords.
-
802.1X
— Indicates that the RADIUS server is used for 802.1X
authentication.
-
All
— Indicates that the RADIUS server is used for authenticating user
name and passwords, and 802.1X port authentication.
Use Default — Uses the default value for the parameter.
STEP 3 Define the relevant fields.
STEP 4 Click Apply. The RADIUS Server is modified, and the device is updated.
Defining Access Methods
The access method section contains the following pages:
Defining Access Profiles
Defining Profile Rules

Table of Contents

Other manuals for Cisco SGE2000 - Cisco - Gigabit Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 - Cisco - Gigabit Switch and is the answer not in the manual?

Cisco SGE2000 - Cisco - Gigabit Switch Specifications

General IconGeneral
Form FactorRack-mountable
Switching Capacity48 Gbps
Forwarding Rate35.7 Mpps
LayerLayer 2
Power SupplyInternal
ManagementWeb-based, SNMP, CLI
MAC Address Table Size8000 entries
VLANs256
FeaturesQuality of Service (QoS), IGMP snooping, Port mirroring
Dimensions (W x D x H)440 x 257 x 44 mm (17.3 x 10.1 x 1.73 in)
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x

Related product manuals