Configuring VLANs
Defining VLAN Interface Settings
Cisco Small Business SFE/SGE Managed Switches Administration Guide 177
6
To Entry Number(s) — Assigns the copied VLAN configuration to the specified
table entry.
Ports of Unit — Indicates that ports on the specified stacking member are
described in the page.
LAGs — Indicates that LAGs are described in the page.
Interface — The port number included in the VLAN.
Interface VLAN Mode — Indicates the port mode. Possible values are:
-
General
— The port can be tagged and untagged with members of one
or more VLANs. (full 802.1Q mode).
-
Access
— The port belongs to a single untagged VLAN. When a port is
in Access mode, the packet types which are accepted on the port
(packet type) cannot be designated. It is also not possible to enable/
disable ingress filtering on an access port.
-
Trunk
— The port can be member of one or more VLANs. It is an
untagged member of at most one VLAN, and is a tagged member of all
other VLANs it is a member of.
-
Customer
— The port can be a member of one or more double tagged
Multicast TV VLAN’s. Refer to
Define Customer VLAN using Q-in-Q
for
details.
PVID — Assigns a VLAN ID to untagged packets. The possible values for
General, Access, and Trunk Interface VLAN Mode are:
-
SGE devices
— 1-4094 and 4095
-
SFE devices
— 1-4093 and 4095
Packets classified to the Discard VLAN are dropped.
Frame Type — Packet type accepted on the port. Possible values are:
-
Admit Tag Only
— Indicates that only tagged packets are accepted on
the port.
-
Admit All
— Indicates that both tagged and untagged packets are
accepted on the port.
Ingress Filtering — Ingress filtering discards packets which do not include an
ingress port. The possible values are:
-
Enable
— Ingress filtering is activated on the port.

Table of Contents

Other manuals for Cisco SGE2000 - Cisco - Gigabit Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 - Cisco - Gigabit Switch and is the answer not in the manual?

Cisco SGE2000 - Cisco - Gigabit Switch Specifications

General IconGeneral
Form FactorRack-mountable
Switching Capacity48 Gbps
Forwarding Rate35.7 Mpps
LayerLayer 2
Power SupplyInternal
ManagementWeb-based, SNMP, CLI
MAC Address Table Size8000 entries
VLANs256
FeaturesQuality of Service (QoS), IGMP snooping, Port mirroring
Dimensions (W x D x H)440 x 257 x 44 mm (17.3 x 10.1 x 1.73 in)
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x

Related product manuals