Configuring SNMP
Defining Trap Management
Cisco Small Business SFE/SGE Managed Switches Administration Guide 321
12
STEP 1 Click System > SNMP > Trap Management > Station Management. The
Station
Management Page
opens:
Station Management Page
The
Station Management Page
contains two areas, the
SNMPv1,2 Notification
Recipient
and the
SNMPv3 Notification Recipient
table.
The
SNMPv1,2 Notification Recipient
table area contains the following fields:
Recipients IP — Indicates the IP address to which the traps are sent.
Notification Type — Defines the notification sent. The possible field values are:
-
Trap
— Indicates traps are sent.
-
Inform
— Indicates informs are sent.
Community String — Identifies the community string of the trap manager.
Notification Version — Determines the trap type. The possible field values are:
-
SNMP V1
— Indicates SNMP Version 1 traps are sent.
-
SNMP V2
— Indicates SNMP Version 2 traps are sent.
UDP Port — Displays the UDP port used to send notifications. The default is
162.

Table of Contents

Other manuals for Cisco SGE2000 - Cisco - Gigabit Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 - Cisco - Gigabit Switch and is the answer not in the manual?

Cisco SGE2000 - Cisco - Gigabit Switch Specifications

General IconGeneral
Form FactorRack-mountable
Switching Capacity48 Gbps
Forwarding Rate35.7 Mpps
LayerLayer 2
Power SupplyInternal
ManagementWeb-based, SNMP, CLI
MAC Address Table Size8000 entries
VLANs256
FeaturesQuality of Service (QoS), IGMP snooping, Port mirroring
Dimensions (W x D x H)440 x 257 x 44 mm (17.3 x 10.1 x 1.73 in)
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90% non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x