Chapter 11  Convenient Functions 
11-65 
11.3.1.4  Modbus Data Exchange – Special Auxiliary Relays  
Device  Name  R/W  Description 
SM1424 
↓ 
SM1455 
Data is being exchanged through 
COM1-Modbus connection Slave 1.   
↓ 
Data is being exchanged through 
COM1-Modbus connection Slave 32. 
R 
ON: Data is being exchanged 
through COM1-Modbus 
connection Slave 1~32. 
SM1456 
↓ 
SM1487 
An error occurs when the data is being read by 
Slave 1 through COM1-Modbus connection. 
↓ 
An error occurs when the data is being read by 
Slave 32 through COM1-Modbus connection. 
R 
ON: An error occurs when data is 
being read by Slave 1~32 through 
COM1-Modbus connection. 
SM1488 
↓ 
SM1519 
An error occurs when data is being written by 
Slave 1 through COM1-Modbus connection. 
↓ 
An error occurs when data is being written by 
Slave 32 through COM1-Modbus connection. 
R 
ON: An error occurs when data is 
being written by Slave 1~32 
through COM1-Modbus 
connection. 
SM1520 
↓ 
SM1551 
Data reading completed by Slave 1 through 
COM1-Modbus connection. 
↓ 
Data reading completed by Slave 32 through 
R 
ON: Data reading completed by 
Slave 1~32 through 
COM1-Modbus connection. 
SM1552 
↓ 
SM1583 
Data writing completed by Slave 1 through 
COM1-Modbus connection. 
↓ 
Data writing completed by Slave 32 through 
R 
ON: Data writing completed by 
Slave 1~32 through 
COM1-Modbus connection. 
SM1598 
Read and write at the same time through 
COM1-Modbus connection. 
R/W 
ON: Enable read and write at the 
same time through 
↓ 
Enable data exchange through COM1-Modbus 
connection slave 1~32. 
R/W 
through COM1-Modbus 
connection slave 1~32. 
SM1752 
↓ 
SM1783 
Data is being exchanged through 
COM2-Modbus connection Slave 1.   
↓ 
Data is being exchanged through 
COM2-Modbus connection Slave 32. 
R 
ON: Data is being exchanged 
through COM2-Modbus 
connection Slave 1~32. 
SM1784 
↓ 
SM1815 
An error occurs when the data is being read by 
Slave 1 through COM2-Modbus connection. 
↓ 
An error occurs when the data is being read by 
Slave 32 through COM2-Modbus connection. 
R 
ON: An error occurs when data is 
being read by Slave 1~32 through 
COM2-Modbus connection. 
SM1816 
↓ 
SM1847 
An error occurs when data is being written by 
Slave 1 through COM2-Modbus connection. 
↓ 
An error occurs when data is being written by 
Slave 32 through COM2-Modbus connection. 
R 
ON: An error occurs when data is 
being written by Slave 1~32 
through COM2-Modbus 
connection. 
SM1848 
↓ 
SM1879 
Data reading completed by Slave 1 through 
COM2-Modbus connection. 
↓ 
Data reading completed by Slave 32 through 
R 
ON: Data reading completed by 
Slave 1~32 through 
COM2-Modbus connection. 
SM1880 
↓ 
SM1911 
Data writing completed by Slave 1 through 
COM2-Modbus connection. 
↓ 
Data writing completed by Slave 32 through 
R 
ON: Data writing completed by 
Slave 1~32 through 
COM2-Modbus connection.