EasyManua.ls Logo

Delta AH500 - 4.13.3.1 External Wiring

Delta AH500
681 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Installing Hardware and Wiring
4-101
Connector on AH04HC-5A
4.13.3.1 External Wiring
1. A PNP encoder is used.
AH04HC-5A high-speed counter modul e
5 ~ 24VDC
A phase
B p hase
5V, 12V, 24VDC
PNP encoder
X0.8+
X0.8-
X0.9+
X0.9-
X0.0+
X0.0-
disable
Start
COM
+24V
OA
OB
OUT
OUT
0V
0V
+24V
Y0.8
C0
Y0.9
C1
Shielded cable
Shielded cable
Shielded cable
External power supplyExternal power supply
Pin Terminal
Function
Pin Terminal
Function
Count
Count
1
C3
COM3
2
Y0.11
Out3
3
C2
COM2
4
Y0.10
Out2
5
C1
COM1
6
Y0.9
Out1
7
C0
COM0
8
Y0.8
Out0
9
-
-
10
-
-
11
-
-
12
-
-
13
X0.3-
Rst3-
14
X0.3+
Rst3+
15
X0.15-
CntB3-
16
X0.15+
CntB3+
17
X0.14-
CntA3-
18
X0.14+
CntA3+
19
X0.2-
Rst2-
20
X0.2+
Rst2+
21
X0.13-
CntB2-
22
X0.13+
CntB2+
23
X0.12-
CntA2-
24
X0.12+
CntA2+
25
X0.1-
Rst1-
26
X0.1+
Rst1+
27
X0.11-
CntB1-
28
X0.11+
CntB1+
29
X0.10-
CntA1-
30
X0.10+
CntA1+
31
X0.0-
Rst0-
32
X0.0+
Rst0+
33
X0.9-
CntB0-
34
X0.9+
CntB0+
35
X0.8-
CntA0-
36
X0.8+
CntA0+

Table of Contents

Other manuals for Delta AH500