AH500 Hardware and Operation Manual
12-74
Error
code
Description
CPU
Status
LED indicator status
ERROR
BUS
FAULT
16#9A4B
There is no response from slave 11 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A4C
There is no response from slave 12 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A4D
There is no response from slave 13 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A4E
There is no response from slave 14 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A4F
There is no response from slave 15 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A50
There is no response from slave 16 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A51
There is no response from slave 17 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A52
There is no response from slave 18 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A53
There is no response from slave 19 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A54
There is no response from slave 20 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A55
There is no response from slave 21 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A56
There is no response from slave 22 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A57
There is no response from slave 23 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A58
There is no response from slave 24 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A59
There is no response from slave 25 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A5A
There is no response from slave 26 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A5B
There is no response from slave 27 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A5C
There is no response from slave 28 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A5D
There is no response from slave 29 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A5E
There is no response from slave 30 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A5F
There is no response from slave 31 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A60
There is no response from slave 32 in the PLC Link /
COM1 MODBUS. (SM1592)
Continue Keep Keep
16#9A61
The setting of the PLC Link / COM1 MODBUS mode is
incorrect. (SM1589)
Continue Keep Keep
16#9A62
The number of polling cycles in the PLC Link / COM1
MODBUS is incorrect. (SM1592)
Continue Keep Keep
16#9A63
There is a handshaking timeout when the CPU module
establishes a connection with the network module.
(SM1596)
Continue Keep Keep