Spanning Tree Configuration
Reviewing and Setting Spanning Tree Bridge Parameters
Matrix E1 Series (1G694-13) Configuration Guide 5-11
5.2.1.6 set spantree hello
Use this command to set the device’s Spanning Tree hello time, This is the time interval (in seconds)
the device will transmit BPDUs indicating it is active.
set spantree hello interval
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set the spantree hello time to 3 seconds:
interval Specifies the number of seconds the system waits before
broadcasting a bridge hello message (a multicast message
indicating that the system is active). The minimum value is
1. The maximum value is the lower of 10 or
[(Max. Message Age / 2) -1].
Matrix>set spantree hello 3
Spanning Tree hello interval set to 3 seconds.