Spanning Tree Configuration
Reviewing and Setting Spanning Tree Port Parameters
Matrix E1 Series (1G694-13) Configuration Guide 5-35
5.2.2.10 set spantree adminpoint
Use this command to set the administrative point-to-point status of the LAN segment attached to a
Spanning Tree port.
set spantree adminpoint port_string {true | false | auto}
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set the LAN attached to front panel port 3 as a point-to-point segment:
port_string Specifies the port(s) for which to set point-to-point protocol
status. For a detailed description of possible port_string
values, refer to Section 4.1.2.
true | false | auto Specifies the point-to-point status of the LAN attached to
the specified port.
true forces the port to be considered point-to-point.
false forces the port to be considered non point-to-point.
auto (the default setting) allows the firmware to
determine the port’s point-to-point status.
Matrix>set spantree adminpoint ge.0.3 true
Success setting admin point-to-point to TRUE for port ge.0.3.

Table of Contents

Other manuals for Enterasys Matrix E1 1G694-13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix E1 1G694-13 and is the answer not in the manual?

Enterasys Matrix E1 1G694-13 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix E1 1G694-13
CategorySwitch
LanguageEnglish

Related product manuals