Startup and General Configuration
Process Overview: CLI Startup and General Configuration
Matrix E1 Series (1G694-13) Configuration Guide 3-5
This example shows how to set the WebView port to 100.
3.1.5 Process Overview: CLI Startup and General Configuration
Use the following steps as a guide to the startup and general configuration process:
1. Starting and navigating the Command Line Interface (CLI) (Section 3.1.6)
2. Setting the login password (Section 3.2.1)
3. Setting basic system information (Section 3.2.2)
4. Setting SNMP community names (Section 3.2.4)
5. Setting SNMP traps (Section 3.2.5)
6. Closing the CLI (Section 3.2.6)
3.1.6 Starting and Navigating the Command Line Interface
3.1.6.1 Using a Console Port Connection
Once you have connected a terminal to the local console port as described in Chapter 2, the initial
startup screen, Figure 3-2, will display. You can now start the Command Line Interface (CLI) by
• Using a default user account, as described in Section 3.1.6.2, or
• Using an administratively-assigned user account as described in Section 3.1.6.3.
Matrix>set webview port 100
Webview port set to 100.
NOTE: By default, this Matrix E1 Series device is configured with two user login
accounts: ro for Read-Only access, and rw for Read-Write access. The default
password is set to a blank string (carriage return). For information on changing these
default settings, refer to Section 3.2.1.1.