Spanning Tree Configuration
Reviewing and Setting Spanning Tree Port Parameters
Matrix E1 Series (1G694-13) Configuration Guide 5-33
5.2.2.8 set spantree adminedge
Use this command to set the edge port administrative status on a Spanning Tree port.
set spantree adminedge port_string {true | false}
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set front panel port 11 as an edge port:
port_string Specifies the edge port. For a detailed description of
possible port_string values, refer to Section 4.1.2.
true | false Enables (true) or disables (false) the specified port as a
Spanning Tree edge port.
Matrix>set spantree adminedge ge.0.11 true
Success setting admin edge to TRUE for port ge.0.3.