Startup and General Configuration
Setting Basic System Information
3-20 Matrix E1 Series (1G694-13) Configuration Guide
3.2.2.9 set system baud
Use this command to set the console port baud rate.
set system baud rate
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set the system baud rate to 19200:
rate Specifies the console baud rate. Valid rates are 9600, 19200,
2400, 4800 and 38400.
Matrix>set system baud 19200
System console port baud rate set to 19200.