TAP Series Switch Command Line Reference
127
12.8 logging buffer
Use this command to specify logging buffer line number. Use the no form of this command to
set logging buffer line number to default value.
Command Syntax
logging buffer CFGLOGLINES
CFGLOGLINES
Line number value
Command Mode
Global Configuration
Default
default is 500, range is 10 to 1000.
Usage
None
Examples
The following shows how to set logging buffer line number to 10:
Switch(config)# logging buffer 10
The following shows how to set logging buffer line number to default value:
Switch(config)# no logging buffer
Related Commands
show logging buffer
12.9 logging file
To enable writing logs into files, use the logging file command in Global Configuration mode.