Chapter 2 Troubleshooting
2.2 Status Code List
2-38
117-340
Controller Error
117-340
Restart Printer
<Controller Error>
HOOK task error.
Replace the
PWB ASSY
FAX
(PL18.1.10)
Replace the
PWBA ESS.
(REP18.1)
117-344
Fax Error
117-344
Restart Printer
<Fax Error>
FLASHFILE task error.
Replace the
PWB ASSY
FAX
(PL18.1.10)
Replace the
PWBA ESS.
(REP18.1)
117-350
Controller Error
117-350
Restart Printer
<Controller Error>
Task initialization (start) error.
Replace the
PWBA ESS.
(REP18.1)
117-361
IIT Parameter Error
117-361
Reset IIT Parameter
<IIT Parameter Verify NG (The IIT Parameter set-
ting value is checked only at the production pro-
cess.)>
IIT registration adjustment value verification NG.
(Checked only at production process)
Replace the
PWBA ESS.
(REP18.1)
If the problem
cannot be
solved, replace
the printer.
117-362
MFP EEPROM Error
117-362
Restart Printer
<EEPROM Sum Check Error>
EEPROM sum check value error.
Replace the
PWBA ESS.
(REP18.1)
If the problem
cannot be
solved, replace
the printer.
117-363
MFP NVM Error
117-363
Restart Printer
<NVM Sum Check Error>
NVM sum check value error.
Replace the
PWBA ESS.
(REP18.1)
If the problem
cannot be
solved, replace
the printer.
117-365
RTC Low Voltage Error
117-365
Restart Printer
<Low Voltage>
RTC detected Low Voltage. RTC clock setting and
content of SRAM are invalid. Initialize them.
Replace the
PWBA ESS.
(REP18.1)
117-367
Controller Error
117-367
Restart Printer
<FXIF error>
An error occurred on FXIF (such as the Video
Underrun error)
Replace the
PWBA ESS.
(REP18.1)
Replace the IIT
ASSY
(REP 21.1)
123-314
Control Panel Error
123-314
Restart Printer
<Panel Power On Error>
Communication error at panel power on.
Startup sequence does not start from AIOC within 1
minute after panel power on.
Replace the
PWBA ESS.
(REP18.1)
Status
Code
LCD Message Name/Description of Error FIP