EasyManua.ls Logo

Fujitsu PRIMERGY RX900 S2 - Page 172

Fujitsu PRIMERGY RX900 S2
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
172 Upgrade and Maintenance Manual RX900 S2
Expansion cards and BBU
© cognitas. Gesellschft für Technik-Dokumentation mbH 2011 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-12050-001.fm
Ê Select the battery holder as follows:
A: Insert the BBU for the Modular RAID controller in PCIe slot #8.
B: Inset the BBU for one of the SAS RAID controllers.
Ê Insert the battery at a slight angle behind the clips (1).
Ê Carefully press the battery into the holder until it engages under the two
locking hooks (2).
Ê Route the BBU cable through the cable clamps (3).
Ê Install the BBU holder with the BBU in the chassis.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX900 S2

Related product manuals