RX900 S2 Upgrade and Maintenance Manual 211
Processors
Ê Place the processor in the socket with great care.
V CAUTION!
Do not move the processor within the socket. This would damage the
spring contacts of the socket. Never touch the underside of the
processor. Even light contaminants, such as oil from human skin, can
destroy the processor or impair its functionality.
Ê Close the processor holder (2).
Ê Lock the processor in the socket by returning the socket lever back into its
original position (3).
10.2.6 Applying the thermal paste
Figure 125: Measuring the thermal paste
Ê Use 0.2 grams of the supplied thermal paste, that is approximately one
graduation mark of the provided application syringe.
One syringe contains thermal paste for 5 processors.
V CAUTION!
Do not apply a mixture of different thermal paste types on the same
processor.
/