5-2
5.1
Outline of ARMS
ARMS (Advanced Registration Mark Sensing System) is a function to scan the registration mark plotted on the
media using sensors.
With ARMS, tilt of the axes and distance can be adjusted with 2 POINTS or 3 POINTS. 2 axes warp adjustment can
be adjusted in addition to axes adjustment (tilt) and distance adjustment with 4 POINTS.
When cutting the outlines of the printed figure, and when re-cutting media, using ARMS to adjust for printing
position discrepancies, high precision cutting/plotting can be done.
It is possible to perform a multiple registration mark adjustment or segment area adjustment by linking with the
application software on the computer. See the operation guides of the application software about the registration
mark adjustment function linked with the application software.
Registration mark scanning accuracy when a designated registration mark is being scanned by this machine is
within 0.3 mm.
Please take note of the following when scanning a registration mark.
• Shape (Pattern) of the Registration Mark and Origin Point
• Scan Range Necessary to Detect the Registration Mark
• Positioning of the Media and the Registration Mark
• Cutting area when adjusting the registration mark
• Automatic detection of registration mark position
• Media That Registration Mark Cannot be Detected