15-24
15.7
Self Diagnostic Test
Operation status can be tested by self-diagnostic test by operating the sensors and switches following the
instruction on the screen.
Diagnostic test can be performed only right after the power is turned on. DIAGNOSTICS cannot be selected from the
menu once any operation, such as loading media, is performed.
Supplement
Operation
1.
Confirm that the power is turned off.
2.
Turn the power on without loading the media.
3.
Press the [ ] icon.
4.
Press the [INFO].
5.
Press the [DIAGNOSTICS].
6.
Press the [START].
7.
Operate the keys and the sensors following the instructions on the screen.
"OK" will be displayed if the correct operation is detected as a result of the operation, and next test will
start.
It will return to the screen shown in step 4 once all the test items are completed.