5-14
Adjust for the registration mark scan position
Sensor to scan the registration mark is positioned away from the tip of the tool. Therefore, it is necessary to adjust
the coordinate values of the scanned registration mark so it will match with the plotting position.
If the registration mark is already marked on the media, scan that registration mark, plot another registration mark
in the same position, and measure the difference between them. This difference is entered as an adjustment value.
If there is no registration mark on the media, plot a registration mark first, scan that registration mark, plot another
registration mark, and measure the difference of them. This difference is entered as an adjustment value.
When using media and tools for actual use, the adjustment accuracy will be higher.
Adjust after plotting the correction registration mark
This section describes the procedure to adjust the registration mark scan position if there is no registration mark on
the media.
See “Adjust using plotted adjustment registration mark” if there is registration mark on the media.
Supplement
Operation
1.
Load white media into the plotter.
2.
Set the water-based fiber pen (black) on the backward of tool holder.
•
Check If the Water-based fiber-tip pen has been scratched.
•
Water-based fiber pen is an optional item.
Supplement
3.
Press the [ ] icon.
4.
Press the [ARMS].
5.
Press the [SENSOR OFFSET ADJ.].
6.
Press the [DRAW].