7-7
7.2
Setting the Step Pass
It may not cut the curved line smoothly if there is very short lines in the curve.
It will cut in the units of the specified value when the STEP PASS is used, which allows to control the short lines with
certain length, resulting to stable rotation of the blade for higher cut quality.
Setting range of STEP PASS is from 0 to 20.
Actual length of the STEP PASS is the value of the STEP PASS multiplied by the distance set in the "STEP SIZE".
This setting will be saved even if the power is shut off.
The cut image may not be what you intended if the set value is too large.
It is recommended to set to "1" for normal use.
Supplement
Operation
1.
Press the [ ] icon.
2.
Press the [CONFIG].
3.
Press the [ ] icon.
4.
Press the [CUT QUALITY].
5.
Press the [STEP PASS].