EasyManua.ls Logo

Kyocera TASKalfa 6501i - Setting Fan Mode

Kyocera TASKalfa 6501i
1149 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2N8/2N7
1-3-48
U059 Setting fan mode
Description
Specifies mode for developer fan motors.
Purpose
Handling the lowering density [to suppress thermal stresses owing to the heated toner]
Method
1. Press the start key.
2. Select the mode.
Setting: [Fan Mode]
1. Select the mode.
Initial setting: Mode1
2. Press the start key. The setting is set.
Setting: [Cooling Mode]
1. Change the setting value using the +/- keys.
A larger value advances the operating timing, and a smaller value slows it.
2. Press the start key. The value is set.
Item No. Description
Display Description
Fan Mode Sets threshold temperature at which developer fan motors oper-
ate.
Cooling Mode Sets temperature at which the developer fan motors are switched
for controlling.
Interval Cycle Varies the timing cycle for controlling the fan
Display Description
Mode1 Setting temperature: Normal
Mode2 Setting temperature: Temperature threshold is raised from mode1
(WUP, temperature at READY: mode1 temperature -7(C), Tempera-
ture at PRINT: mode1 temperature -3(C).)
Mode3 Setting temperature: Temperature threshold is raised from mode2
(WUP, temperature at READY: mode1 temperature -22(C), Temper-
ature at PRINT: mode1 temperature -8(C).)
Auto Starting with Mode 2 at power up or recovery from sleep mode, and
switches to Mode 3 when the thermistor detects a developer temper-
ature BK is equal to or higher than 38C. The device never reverts
from mode 2 from mode 3 while power is on.
Display Description
Setting
range
Initial
setting
Cooling Mode Amount of shift from the initial standard
temperature
-3 to 3 (C) 0