2N8/2N7-6
1-4-251
(2-7) U017XX error code table: V.34 transmission
U01700/E01700:A communication error that occurs at the transmitting unit in the period after transmission of
INFO0 before entering phase 3 (primary channel equivalent device training). For example,
INFO0/A/Abar (B/Bbar, for polling transmission)/INFOh was not detected.
U01720/E01720:A communication error that occurs at the transmitting unit in the period after initiating the
control channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not
detected.
U01721/E01721:In the absence of a common communication speed between units (including when an impos-
sible combination of communication speed and symbol speed occurs) after MPh exchange;
1) a DCN signal was received from the destination unit, and the line was cut; or 2) a DIS
(NSF, CSI) signal was received from the destination unit and, in response to the signal, the
unit transmitted a DCN signal, and the line was cut.
(2-8) U018XX error code table: V.34 reception
U01800/E01800:A communication error that occurs at the receiver unit in the period after transmission of
INFO0 before entering phase 3 (primary channel equivalent device training). For example,
INFO0/B/Bbar (A/Abar, for polling reception)/probing tone was not detected.
U01810/E01810:A communication error that occurs at the receiver unit in phase 3 (primary channel equiva-
lent device training). For example, S/Sbar/PP/TRN was not detected.
U01820/E01820:A communication error that occurs at the receiver unit in the period after initiating the control
channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected.
U01821/E01821:In the absence of a common communication speed between units (including when an impos-
sible combination of communication speed and symbol speed occurs) after MPh exchange, a
DCN signal was transmitted to the destination unit and the line was cut.
Error code Description
U01700/E01700 A communication error occurred in phase 2 (line probing).
U01720/E01720 A communication error occurred in phase 4 (modem parameter exchange).
U01721/E01721 Operation was interrupted due to the absence of a common communication speed
between units.
Error code Description
U01800/E01800 A communication error occurred in phase 2 (line probing).
U01810/E01810 A communication error occurred in phase 3 (primary channel equivalent device training).
U01820/E01820 A communication error occurred in phase 4 (modem parameter exchange).
U01821/E01821 Operation was interrupted due to the absence of a common communication speed
between units.

Table of Contents

Other manuals for Kyocera TASKalfa 6501i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera TASKalfa 6501i and is the answer not in the manual?

Kyocera TASKalfa 6501i Specifications

General IconGeneral
Web InterfaceYes
PRESCRIBEYes
Operating System CompatibilityWindows, macOS, Linux
Print DriverKX Driver
Mobile PrintingKYOCERA Mobile Print, AirPrint, Mopria
EmulationsPCL6 (5e/XL), KPDL3 (PostScript 3 compatible), XPS, PDF Direct Print
Fonts1 Bitmap font
Accounting1, 000
Print LanguagePCL6, PostScript 3, KPDL, XPS
Scan File FormatsTIFF, PDF, PDF/A, JPEG, XPS
Scan Resolution600 x 600 dpi
Network ProtocolsTCP/IP
Security FeaturesIPsec, SSL