2N8/2N7-3
1-3-94
U161
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U164 Fuser Unit History
Description
Displays the past record of machine number and the fuser counter.
Purpose
To check the count value of machine number and the fuser counter.
Method
1. Press the start key.
The history of a machine number and a fuser counter is displayed by three cases.
Completion
Press the stop key.
The screen for selecting a maintenance item No. is displayed.
U165 Fuser Unit Number
Description
Displays the fuser unit number.
Purpose
To check the fuser unit number.
Method
1. Press the start key. The fuser unit number is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Temperature to Acti-
vate Aging
Less than
11+α°C
Less than
16+α°C
16+α°C or more
Time for Low-tempera-
ture Aging
45 sec 35 sec 0 sec
Display Description
Machine History1 - 3 Historical records of the machine number
Cnt History1 - 3 Historical records of fuser counter