2N8/2N7
1-3-132
U250 Checking/clearing the maintenance cycle
Description
Changes preset values for maintenance cycle and automatic grayscale adjustment.
Purpose
Provides changing the time when the message to acknowledge to conduct maintenance and
automatic grayscale adjustment is periodically displayed.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +- keys or numeric keys.
4. Press the start key. The value is set.
Clearing
1. Select [Clear].
2. Press the start key. The setting value is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
* : Cassette 1 to 7:
When the firmware is upgraded in the field, the standard counter value newly added
should be set to 150000.
Item No. Description
Display Description Setting
range
Initial setting
M.Cnt A Preset values for maintenance cycle (kit A) 0 to 9999999 600000
M.Cnt C Preset values for maintenance cycle (kit C) 0 to 9999999 300000
M.Cnt HT Preset values for automatic grayscale
adjustment
0 to 9999999 0
Cassette 1 Maintenance counter cassette1 0 to 9999999 150000
Cassette 2 Maintenance counter cassette1 0 to 9999999 150000
Cassette 3 Maintenance counter cassette1 0 to 9999999 150000
Cassette 4 Maintenance counter cassette1 0 to 9999999 150000
Cassette 5 Maintenance counter cassette5 0 to 9999999 150000
Cassette 6 Maintenance counter cassette6 0 to 9999999 150000
Cassette 7 Maintenance counter cassette7 0 to 9999999 150000
Clear Maintenance counter all clear 0 to 9999999 -