2N8/2N7-3
1-3-93
U161 Setting: [Print]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
3. Press the start key. The value is set.
Setting: [Low Power Mode]
1. Select the item to be set.
Initial setting: Mode0
2. Press the start key. The setting is set.
Setting: [Belt Mode]
1. Select the item to be set.
* : Initial setting: Off
* : On: The fuser motor should be deactivated after 15 minutes in Ready state so that the
fuser belt refrains from revolving.
2. Press the start key. The setting is set.
Setting: [Ready Time Adjust]
1. Change the setting value using the +/- or numeric keys.
2. Press the start key. The setting is set.
* : Reducing the alpha value lowers the temperature at which aging is activated following the
quiet mode has been stable.
* : Lowering the alpha value could deteriorate the fuser performance due to aging would not
be activated during quiet mode.
Item No. Description
Display Description
Setting
range
Initial setting
65ppm 80ppm
Full Speed
Print(Center)
Temperature at maximum
print speed (Center)
130 to 200
(°C)
165 170
Duplex Shift
(Center)
Temperature at duplex
printing (Center)
-20 to 20
(°C)
00
Display Description
Mode0 Present state control mode (Usually not used)
Mode1 Fuser control temperature reduction mode (For normal users)
Mode2 Large volume output mode (For users who repeatedly print
approximately 1500 sheets at a time)
Display Description
On
Belt mode is performed
Off
Belt mode is not performed
Display Description
Setting
range
Initial
setting
Value Compensating Values for the Activating Tem-
perature for Low-temperature Aging: (α)
0 to 2 2