2N8/2N7
1-3-178
U465 Data reference for ID correction
Description
References the data related to ID correction.
Purpose
To check the corresponding data.
Method
1. Press the start key.
2. Select the item to be reference.
Displaying: [TCOUNT]
Select [TCOUNT]. The current value is displayed.
Displaying: [Laser Power]
1. Select [Laser Power]. The current value is displayed.
Displaying: [Bias Calib]
1. Select [Bias Calib]. The current value is displayed.
Displaying: [T7 CTD]
1. Select [T7 CTD]. The current value is displayed.
Completion
Press the stop key.
* : The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
TCONT Developer bias control value after ID correction
Laser Power Scaling factor to the value determined in light amount calibration
Bias Calib Sensor value for toner thick layer calibration
T7 CTD T7 control value
Display Description
Before(K) Developer bias control value before ID correction
After(K) Developer bias control value after ID correction
Display Description
K Scaling factor to the value determined in light amount calibration
Display Description
K Sensor value for toner thick layer calibration
Display Description
K T7 control value