2N8/2N7-6
1-4-250
(2-6) U011XX error code table: G3 reception
Error code Description
U01100/E01100 Function of the unit differs from that indicated by a DCS signal.
U01101/E01101 Function of the unit (excl. communication mode select) differs from that indicated by an
NSS signal.
U01102/E01102 A DTC (NSC) signal was received when no transmission data was in the unit.
U01110/E01110 No response after transmission of a DIS signal.
U01111/E01111 No response after transmission of a DTC (NSC) signal.
U01113/E01113 No response after transmission of an FTT signal.
U01125/E01125 No response after transmission of a CNS signal (between units of our make).
U01129/E01129 No response after transmission of an SPA signal (short protocol).
U01141/E01141 A DCN signal was received after transmission of a DTC signal.
U01143/E01143 A DCN signal was received after transmission of an FTT signal.
U01155/E01155 A DCN signal was received after transmission of an SPA signal (short protocol).
U01160/E01160 During message reception, transmission time exceeded the maximum transmission time
per line.
U01162/E01162 Reception was aborted due to a modem malfunction during message reception.
U01191/E01191 Communication was interrupted because an error occurred during an image data recep-
tion sequence in the V.34 mode.
U01193/E01193 There was no response, or a DCN signal or invalid command was received, during
phase C/D of reception.
U01194/E01194 A DCN signal was received during phase B of reception.
U01195/E01195 No message was received during phase C of reception.
U01196/E01196 Error line control was exceeded and a decoding error occurred for the message being
received.