2N8/2N7-6
1-5-43
19. Refit the scanner wire drum with two
screws.
20. Remove the two scanner wire stoppers
and frame securing tools.
21. Focusing on the locating ball of the wire
drum, align the scanner wires to the
inside.
22. Move the mirror 2 frame from side to
side to correctly locate the wires in posi-
tion.
23. Refit the mirror 1 frame.
24. Move the mirror 1 and 2 frames to the
machine left, and insert the two frame
securing tools into the positioning holes
at the front and rear of the scanner unit
to secure the frames in position.
25. Hold the wires and fix each front and
rear wire holder plate to mirror 1 frame
with the screw.
26. Remove the two frame securing tools.
27. Refit the exposure lamp.
Figure 1-5-70
Mirror 1 frame
Mirror 1 frame
Mirror 2 frame
Mirror 2 frame
Front wire holder plate
Screw
Rear wire holder plate
Screw
Frame securing tool
Frame securing tool
OK