3-14 Service Manual
7525-63x
Go Back
Previous
Next
Scanner Calibration
Copy Quick Test
This test performs a copy from the scanner flatbed or duplex ADF using the printer’s current settings.
To perform this test, navigate to Diag Menu > Scanner Calibration > Copy Quick Test.
Adjust Calibration Values
This setting adjusts the black value (mono and color bands) used in the gamma curve for a specific scan source.
This should only be used to manually tune a replacement scanner’s black gamma value.
To adjust these settings:
1. Navigate to Diag Menu > Scanner Calibration > Adjust Calibration Values.
2. Touch or to adjust the settings of the following:
• Flatbed Black
• ADF Front Black
• ADF Back Black
3. Touch Submit to save the settings, or touch Back to return to Scanner Calibration without saving any
changes.
Reset Flatbed, ADF Front, ADF Back Calibration Values
These settings revert the selected scan source’s IQT-related black values to Nominal Black setting and its white
values to Nominal White setting.
Note: This operation should be performed only when the printer’s scanner has been replaced.
To reset these settings:
1. Navigate to Diag Menu > Scanner Calibration.
2. Touch Reset Flatbed Calibration Values, Reset ADF Front Calibration Values, or Reset ADF Back
Calibration Values.
3. Scanner calibration values should only be reset when the scanner is replaced. All customized
scanner calibration data will be lost. Do you wish to continue? appears. Touch Yes to reset the
settings, or touch No to return to Scanner Calibration.
MISC TESTS
Motor Detect
This test initiates an automatic motor detection process that should be performed whenever the RIP board is
replaced.
To run the test:
1. Navigate to MISC TESTS.
2. Touch Motor Detect.
3. Motor Detection In Progress appears. The process takes about 10 seconds, and stops automatically.
4. Motor Auto Detect Test Passed appears, and the display returns to MISC TESTS.

Table of Contents

Other manuals for Lexmark X548 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexmark X548 Series and is the answer not in the manual?

Lexmark X548 Series Specifications

General IconGeneral
BrandLexmark
ModelX548 Series
CategoryAll in One Printer
LanguageEnglish

Related product manuals