General information 1-7
7525-63x
Power and electrical specifications
The following table specifies nominal average power requirements for the base printer configurations. All power
levels are shown in Watts (W). Maximum current is given in Amperes (A).
Low-voltage models
• 100–127 V (100–110 Japan) at 50–60 Hz, nominal
• 90–137 V (90–110 Japan), extreme
100-volt models
• 100 V ac at 47–63 Hz nominal
• 90–110 V ac, extreme
High-voltage models
• 220–240 V ac at 50–60 Hz nominal (not available in all countries)
• 198–259 V ac, extreme
Notes:
• Using a 220 V ac to 110 V ac power converter with a low voltage printer is not recommended.
• Using an inverter to change DC to AC voltage (12 V to 120 V for example) is not recommended.
• All X54x MFP models will comply with the ENERGY STAR.
• All models ship with Power Saver Mode = On.
• The default timeout to Power Saver = 60 minutes (220 V).
• Power Saver can be adjusted to 1–240 minutes.
• Power Saver mode cannot be disabled from the operator panel.
Printing states
Off 0.2 W
Sleep state 23 W
Ready state 50 W
Simplex printing 540 W
Duplex printing 380 W
Copying 530 W
ADF scanning 60 W
Typical electricity consumption test 5.13 kWh/week
Maximum (ave.) current while printing:
100–110 V
115–127 V
220–240 V
8.2 A
7.2 A
3.6 A